INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)
SECTION I
I. DESCRIPTION AND SCOPE
Model SCV-S is a pneumatically actuated, globe-style
con trol valve for throttling sanitary or biotechnological
ap pli ca tions. The globe body comes in two variations
- straight-globe pattern and angle-globe pattern, sizes
3/4" - 1-1/2" (DN20 - DN40) with standard Tri-Clover®
sanitary end connections. The valve is available in
either a metal or composition seat construction. The
wetted metallic body portion is of forged 316L SST
mechanically and electro-polished to a 10 micro-inch
R
a
nish.
A eld reversible actuator, Model C27 is mounted
to the body.
Failure position is determined by actuator for:
"D" = Direct action; on increasing air loading pressure,
the actuator stem extends. Fail-safe position is with
the stem retracted.
"R" = Reverse action; on increasing air loading pres-
sure, the actuator stem retracts. Fail-safe position is
with the stem extended.
The standard actuator stem-to-valve stem connection
is a screwed joint design; Opt.-68 Quick Disconnect
Joint is also available.
II. REFERENCE
Refer to Technical Bulletin SCV-S-TB for complete
tech ni cal speci cations.
www.cashco.com/techbulletins/scvs.pdf
Refer to following Installation, Operation & Main te-
nance Manuals (IOM’s) for the actuator and/or devices
that maybe mounted to a Model SCV-S:
Actuators: www.cashco.com/IOM/C27-C53.pdf
Positioners:
P/P: www.cashco.com/techbulletins/9540l.pdf
I/P: www.cashco.com/techbulletins/srd991.pdf
I/P: www.cashco.com/iom/PS2iom.pdf
ABBREVIATIONS
ATC-FO - Air to Close, Fail Open
ATO-FC - Air to Open, Fail Close
CCW - Counter-Clockwise
CIP - Clean-in-Place
CW - Clockwise
DIR - Direct Acting
IAS - Instrument Air Supply
REV - Reverse Acting
SIG - Output Signal from Instrument
SIP - Steam-in-Place
V - Vent
Straight Body Pattern
with ATC - FO Actuator
IOM-SCV-S
12-13
MODEL SCV-S
GLOBE-STYLE - SANITARY
PNEUMATIC CONTROL VALVE
BODY IOM
SECTION II
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - MODEL SCV-S

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) SECTION II. DESCRIPTION AND SCOPEModel SCV-S is a pneumatically actuated, globe-style con

Página 2 - IV. INSTALLATION

IOM-SCV-S10 5. Inadequate valve shutoff. Possible Cause Remedy A. Permanent "tracks" where seating occurs. A1. Relap body

Página 3 - V. MAINTENANCE

11IOM-SCV-SNEW REPLACEMENT UNIT:Contact your local Cashco, Inc., Sales Rep re sen- ta tive with the Serial Number and Product code. With this informa

Página 4

IOM-SCV-S12 REPLACEMENT ITEM NO. DESCRIPTION PARTS 1 Body 2 Bonnet 3 Stem/Metal Plug * 4 “Tri-Clover” Clamp 7 Gasket * 8 Yoke Nut 9 Sea

Página 5 - Figure 3 : Clamp Orientation

IOM-SCV-S2Figure 1: Installation OrientationSECTION IIISECTION IVIV. INSTALLATIONA. Orientation:1. Standard orientation is with the yoke with positio

Página 6

3IOM-SCV-SSECTION V1. Maintenance procedures hereinafter are based upon removal of the control valve unit from the piping system where installed. 2.

Página 7 - VI. CALIBRATION

IOM-SCV-S4from the plug/stem (3), while holding the actuator stem (6). Record the num ber of plug/stem rev o lu tions for Step A above. When the dis

Página 8 - For Std Threaded Stem:

5IOM-SCV-SPlace new seat disc on threaded end of plug and re-install in nut. Place stem on threaded end of plug and secure tight. Special care must

Página 9

IOM-SCV-S6with bonnet (2) by checking OD of fl anges. Finger-tighten clamp nuts (4.3). NOTE: Gap be tween clamp (4.1) halves should be equal in size. S

Página 10 - SEC TION VII

7IOM-SCV-SSECTION VIVI. CALIBRATIONA. General:1. This section only covers cal i bra tion of the control valve with Actuator Model C27-C53.2. Position

Página 11 - SECTION VIII

IOM-SCV-S8(16) to the "C" mark on the in di ca tor plate (23), mak ing sure to use the “top edge” of the in di ca ting washer (16) as the r

Página 12

9IOM-SCV-Sd. Rotate upper jam nut CW to hold indica-tor washer (16) up against stem (6).e. Release all pressure from the actuator and repeat Step 4 p